EVOLVE Electrical Customer Ideas
Our products depend on your feedback. No idea is too small or too big, we want to know where to make improvements and what features mean the most to our end users. Our customers drive our road map, thanks for sharing!
Place Connectors Button
Automatically size and place connectors on selected end of conduit run.
I see this being a huge time saver when we have multiple conduits entering / exiting a ...
Run Schedule Remember Path per Project
Currently when importing a run schedule the folder path is set to the last path used to import a feeder schedule. For users that work on multiple projects this ...
Cable Tray Physical Size
Cable tray physical size is needed for coordination. Currently the tray is exact size to the trade size name.
Basket Tray min, 1" sides and bottom.
Ladder Tray min, ...
Modifying Packages - Nested Elements
When modifying a package, if you remove an element that has nested components, those components are not removed from the package and needs to be selected manually. ...
ConduitRun_start auto-populate with connected equipment
Would like the conduitRun_Start and finish to autopopulate with connected equipment data.
Renumber Parallel Feeders in 1 Action
Using the renumber tool, I am renumbering each stick of conduit with a unique ID. When renumbering parallel feeders, it would save a lot of time if we can renumber ...
Work in Revit While having GUI's open.
Can we make it so that when we are manipulating the conduit run schedule or any of the GUI's that you can still work in revit and be able to do R&D with it.
Add the 3 d submittal text to the plan view for equipment and light fixtures.
It is nice that you have the Check box or X that shows in 3d whther or not the submittal is approved but it would be even better if it showed in plan view so that ...
Incorporate connector option into bend family, this should work like the coupling feature.
it would save time when stubbing down to panels or into boxes with conduit bends to have the option of selecting to have a connector or a coupling on either end of ...
Add B22B configuration to strut family
add B22B config to strut family
Hanger collision detection
Is it possible to have trapeze collision detection monitor loaded coordination models (NWCs,NWDs etc) instead of/as well as revit models.
Import Conduit Run Schedule Function to come from Excel or Google Sheets
Our company uses Google Sheets for our Conduit Schedules. So it would save us a lot of steps to have this function.
Modify Spool Window rfa to allow multiple views of the same type
By modifying the spool window family it is possible to create multiple views of the same type on a single spool i.e multiple "Elevation Top" views. This is necessary ...
Kicked 90s. Make reversed fixed end and reverse direction one button since they are dependent on ea
Removes the need to remember to check both and will not brake conduit fitting
Exapnd "Element Filter Hot Keys" feature to include non-alphanumeric characters
Improvements in ui/ux would greatly benefit this tool. There is no clear documentation on how to activate the hot key function. The function also seems to activate ...
Connect conduits on conduit runs of varying sizes
I would be nice if we have the ability to connect the conduit runs (comprising of 5+ conduits of varying sizes and elevations), based on the property of a chosen ...
extend bolt lengths to 6"
extend bolt length options to 6" length